Port collisions between Chinaski instances (or between Chinaski and other software) show up as a service that won’t start, an admin UI that never answers, or a proxy that reports the backend unreachable. This page explains which ports Chinaski uses by default, where the port actually gets chosen, and how to diagnose and fix the usual conflicts.

## Which port is which

Chinaski has a few different “ports” in play, and they belong to different layers:

- **The CMS daemon** listens on the address in `/etc/chinaski/env` (`LISTEN_URL`), which is the only place it’s set at runtime for a systemd deployment. With the standard installer, the instance port is derived automatically: numeric names get `3000 + N` (instance `2` → 3002), non-numeric names get 3001; pass `--port` to override.
- **Quick installs / offline bundles** (no reverse proxy, hypnotoad direct) listen on **8080** by default, on all interfaces until you narrow it.
- **Caddy or nginx** own 80/443 and reverse-proxy to the per-instance loopback port.
- **The MCP server binds no port at all**: it connects out to the CMS’s URL; only its `CHINASKI_API_URL` references a port.

## Common symptoms and causes

**The service unit flaps or fails shortly after start.** Something else already holds the port. After five failed starts within a minute the unit stops retrying and enters a failed state: `systemctl status chinaski@` plus the journal shows the story. Check who has the port with `ss -tlnp | grep :300` (the production checklist’s own diagnostic). Fix by moving either party: set a different `LISTEN_URL` in the instance’s env file, or stop/repurpose the conflicting listener before restarting.

**The admin or public site answers 502-style errors after a port change.** The proxy no longer matches the backend. The generated Caddy example names this explicitly: its upstream address must equal the bind address in the instance’s env file. Change one side and not the other (e.g. you edit `/etc/chinaski1/env` to a new port but not the Caddyfile), and the proxy keeps dialing the old port. Fix: edit both the env file and the proxy upstream, then restart the CMS and reload the proxy. Verify with `ss -tlnp | grep :300` that the daemon is now bound, and with `journalctl -u chinaski@` that it stayed up.

**Two instances collide after a manual re-install.** If the second instance was installed without letting the installer pick a port (e.g. a non-numeric name or a reused `--port`), it shares the first’s port. Each instance needs its own port; the Caddyfile example spells out the expected allocation (instance 1 → 3001, instance 2 → 3002 …) so each new instance should land on the next free 3000-series port.

**The site listens but nobody outside can reach it.** Not a conflict at all: production installs bind the CMS to loopback on purpose (`http://127.0.0.1:3001`), with the reverse proxy accepting the world’s traffic. Widen the bind to `0.0.0.0` and it will “start working”, while also letting any client spoof forwarded headers and defeat IP-based rate limiting and login lockouts. The correct fix for remote access is to proxy through Caddy/nginx, not to widen the bind.

## Changing ports cleanly

1. Decide the new port per instance and update `LISTEN_URL` in `/etc/chinaski/env`.
2. Update the matching proxy upstream (`127.0.0.1:`) on the Caddy/nginx side.
3. Restart the CMS unit and reload or restart the proxy.
4. If the new port needs firewall access for a non-proxy edge case, mirror the firewall rule to the same port: the installer’s own guidance routes every language vhost’s traffic to that one port.

Remember that the production units run the daemon as the dedicated `chinaski` user with a hardened sandbox, so pick high ports (like the 3000-series convention above) for the CMS backend rather than system-level ports.

## A quick diagnosis recipe

```
systemctl status chinaski@<N>            # is the unit in a restart loop / failed?
journalctl -u chinaski@<N> --since today # what did the daemon say at startup?
ss -tlnp | grep -E ':(3000|3001|3002|8080)'   # who owns which port now?
```

If the expected port is held by the right process but the proxy still errors, compare the proxy’s upstream line against the env file’s `LISTEN_URL`: a mismatch there is the single most common cause of “backend running but site down”.